MAK-6571C AUTOMATIC DISTORTION METER

Switchover of the input frequencies, 400Hz or 1000Hz is automatic

< Distortion Measurements >

Fundamental Frequencies 400Hz, 1000Hz and option ( choice of one frequency, namely, THD or 3rd harmonic of 300, 315, 333Hz or 1, 2, 3kHz )

¡@

Measuring Range   0.1% to 30% in 6 ranges
Input Level Range   3mV to 100Vrms in 9 ranges
Fundamental Rejection Characteristics   < -76dB at 400 and 1000Hz

< Level Measurements >

Frequency Range   20Hz to 100kHz : ¡Ó1dB ( ref. 1kHz )
Measuring Range   1mVrms to 100Vrms in 9 ranges
Accuracy of Measurements   ¡Ó3% of f.s. at each ranges
Dimensions & Weight   Approx. 290W¡Ñ160H¡Ñ290Dmm ¡P 5.9kgs

MAK-6571W 2-CHANNEL AUTOMATIC DISTORTION METER

Simultaneous measurements of distortion or level for two channels

< Distortion Measurements >

Fundamental Frequencies 400Hz, 1000Hz and option ( choice of one frequency, namely, THD or 3rd harmonic of 300, 315, 333Hz or 1, 2, 3kHz )
¡@

Measuring Range   0.1% to 30% in 6 ranges
Input Level Range   3mV to 100Vrms in 9 ranges
Fundamental Rejection Characteristics   < -76dB at 400 and 1000Hz
< Level Measurements >
Frequency Range   20Hz to 100kHz : ¡Ó1dB ( ref. 1kHz )
Measuring Range   1mVrms to 100Vrms in 9 ranges
Accuracy of Measurements   ¡Ó3% of f.s. at each ranges
Dimensions & Weight   Approx. 290W¡Ñ160H¡Ñ290Dmm ¡P 7.3kgs